Dc Motor Speed Controller Pwm Speed Controller Forward Reverse Motor Controller 60A 10-55V DC Brush Motor Speed Controller Digital LCD Slow Run/Stop Timer Reversible

Dc Motor Speed Controller Pwm Speed Controller Forward Reverse Motor Controller 60A 10-55V DC Brush Motor Speed Controller Digital LCD Slow Run/Stop Timer Reversible
sku: 1321388885
ACCORDING TO OUR RECORDS THIS PRODUCT IS NOT AVAILABLE NOW
$14.97
Shipping from: United States
   Description
dc motor speed controller pwm speed controller forward reverse motor controller 60A 10-55V DC Brush Motor Speed Controller Digital LCD Slow Run/Stop Timer Reversible Specification: Item Type: DC Motor Speed Controller Input Voltage: DC10-55V the specific voltage must be equal to the rated voltage of the motor Output Voltage: Linear under load Instantaneous Current: 60A Continuous Current: Less than or equal to 40A Speed Regulation Type: Current Regulation Speed Adjustment Method: Jog + - Timing: Yes Limit Function: Yes Slow Run Slow Stop: Can be set Speed Digital Display: 0-100 percentage Speed Range: 0-100% Control Frequency: 15KHZ Connection Type: Fence type terminal Support Motor: Brush Motor Module Size: 148x95x36mm / 5.83x3.74x1.42in Mounting Size: 142x88mm / 5.59x3.46in Installation Method: Embedded Function: 0-1-2-3-4-5-6-7-8-9 function settings are as follows: Manual Automatic Mode Selection Function 0: 1 is manual mode 2 is automatic mode default is manual mode. Slow Run Time Setting Function 1: 000-100 slow start to 100% speed time 0-10s default is 1s. Slow Run Time Setting Function 2: 000-100 slow stop time 0-10s default is 1s. Speed Lower Limit Setting Function 3: 000-080 minimum speed 0-80% and less than the maximum speed setting value default is 0. Speed Upper Limit Setting Function 4: 000-100 maximum speed 0-100% and greater than the minimum speed setting value default is 100%. Acceleration/Deceleration Value Setting Function 5: 001 002 005 010 015 020 025 each time the key increase/reduce is pressed the speed changes by 1% 2% 5% 10% 15% 20% 25%. Motor Running Time Setting Function 6: 1s to 99h 59min default is 99h 59min . The following functions 7-8-9 are time setting in automatic mode Forward Rotation Time Setting Function 7: 0s-99h default is 10s Stop Time Setting Function 8: 0s-99h default is 10s Reverse Rotation Time Setting Function 9: 0s-99h default is 10s Limit Mode Selection Function E: E1: No limit default is no limit E2: After pressing start the motor rotates forward to the forward limit and stops. After pressing start again the motor rotated reverse E3: After pressing start the motor rotates forward to the forward limit and then rotates reverse to the reverse limit finally motor stops E4: After pressing start the motor rotates forward to the forward limit and then rotates reverse cycle working Package List: 1 x Motor Speed Controller Note: The input positive pole and negative pole must be connected correctly. The input voltage10V-55V must be equal to the rated voltage of the motor.
   Price history chart & currency exchange rate

Customers also viewed