DC 12V 2.5W Car Solenoid Air Valve 5 Port 2 Position

DC 12V 2.5W Car Solenoid Air Valve 5 Port 2 Position
Eachine1
sku: 928616
$7.92
Shipping from: China
   Description
DC 12V 2.5W Solenoid Air Valve 5port 2position BSP 4V110-06 Pilot-operated Type Specifications: Material: Alloy Steel Color: Like the picture show Quantity: 1 pc Size(LxWxH): 9.4cm x 1.8cm x2.6cm / 3.7" x 0.7" x 1.02" Wire length: 33cm / 12.99" Packing box dimension(LxWxH): 10cm x 5.6cm x 2cm Model: 4V110-06 Positions: 5 ports/2 positions Motion Pattern: Pilot-operated Type Wiring Form: screw thread type Voltage: DC 12V Allowable Voltage Fluctuation: 10% of Rated Voltage Power Consumption: AC:2.5VA / DC2.5W Operating Tempe: -5 to + 50C / 41-122F Effective Section Area: 12mm (CV=0.67) Port Size: Air Inlet=Air Outlet=Exhaust=1/8"BSP Working Media/Fluld: 40 Micron Filtered Air Operating Pressure: 0.15-0.8 MPa / 22-116 PSI Max. Pressure Resistance: 1.2MPa / 174 PSI Insulation and Protection Class: F Class / IP65 Highest Action Frequency: 5/s Shortest Excitation Time: 0.05 second Feature: Pilot-operated Type: external and internal optional Strut structure, good sealing, responsive Three-position solenoid valve has three central features to choose from Double two position solenoid valve with memory function The hole using a special process, friction resistance, low starting pressure, long life Can be integrated with the base valve, saving installation space Has a manual device, installation and commissioning conducive Trouble Shooting: 1.After energizing the solenoid valve does not work: Check the power wiring is bad Re-connect wiring and connectors Check the power supply voltage in the range of work To adjust the range of the normal position Coils are sealing off Re-welded Coil shorted Replace the coil Working pressure difference is not appropriate Adjust the pressure differential/Replace solenoid valve The fluid temperature is too high Replace solenoid valve Have impurities to make electromagnetic valve of the main valve core and the moving core card to death Cleaning,such as sealing damage the seal and install the filter should be changed Liquid viscosity is too large,the frequency is too high and had come to life Replacement product 2.Solenoid valve can not be closed: The main valve core or moving iron core of seal is damaged Replace the seal The fluid temperature, viscosity is too high Replacement of the solenoid valve Are valve core production impurities into the solenoid valve or moving iron core cleaning Spring life have to or deformation change Orifice balance hole plug In a timely manner to clean Working frequency is too high or have to life Reelection products or product updates 3.Other cases: Internal leakage Check whether the seal is damaged, the spring is bad assembly External leakage Joint looseness or seal has been bad Screws or replace the seal Electricity from time to tome noise The head of the fasteners loose,tighten Package includes: 1 x Solenoid Air Valve 5port 2position
   Price history chart & currency exchange rate

Customers also viewed