CyberPower PR1000RTXL2U 1000VA/1000W Smart App Sinewave UPS w/Extended Battery
The PR1000RTXL2U is a Smart App Sinewave rack/tower convertible UPS with line-interactive topology, surge protection, & battery backup. CyberPower's Smart App Sinewave series has sine wave output to eliminate power gaps that can be detected by sensitive equipment and cause unexpected shutdowns.The Smart App Sinewave PR1000RTXL2U improves battery life through battery equalization technology & Automatic Voltage Regulation (AVR), which corrects minor power fluctuations without switching to battery power. The enhanced chassis design with an easy-to-access toolless front panel, captive screws for battery panel access, & color-coded rear panel make battery changes and installations simple & fast. The PR1000RTXL2U also has an innovative LCD panel that rotates 90 Degree , tilts for a better viewing angle, & provides information on 47 different settings including UPS stats, UPS setup & control management, and testing options.This model accepts the BP48VP2U01 Extended Battery Module (EBM) for expanded runtime during power outages & the RMCARD205 network management card for remote management & d control via a standard web browser or network management system.Battery BackupSupplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data & minimizes the component stress caused by a hard shutdown.Line-Interactive TopologyExists when a line-interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) & over voltages (e.g., spikes) without having to switch to battery.
Automatic Voltage Regulation (AVR)
Provides clean, consistent AC power by automatically increasing (boosting) low voltage without using battery power when incoming utility power experiences minor fluctuations.Sine Wave Output
Provides power protection to ENERGY STAR 6.0 systems with Active PFC power supplies.
Battery Equalization Technology
Battery Equalization is an advanced charging process that maintains the voltages of the batteries at the same level to increase battery life.
Fast Charge Technology
Allows UPS batteries to return to full capacity more rapidly by using a built-in charger inside of each UPS or EBM.Rotatable Multifunction LCD Panel
Tilts to provide a better viewing angle when the Smart App Sinewave is mounted low. Rotates 90 Degree when placed in a tower format for horizontal viewing. Provides information on 47 different settings that include UPS status, UPS setup and control management, & testing options.Toolless Battery Panel Access
Makes battery replacement fast and simple. The faceplate features side latches for easy removal, & captive screws can be loosened by hand to open the battery cover.Extended Battery Modules (EBMs)
Use Fast Charge Technology to quickly restore full backup power to a UPS system. They also extend runtime.Surge ProtectionDiverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.Data-Line ProtectionPrevents power surges that travel through telephone, coaxial, and/or Ethernet lines from causing damage to electronics.GreenPower UPS Bypass Design
Is a patented design that allows utility power to bypass the UPS transformer, when AC power is stable, which reduces energy consumption, noise, & heat buildup.Rack/Tower VersatilityAllows for horizontal rack or vertical tower installation.PowerPanel Business Edition SoftwareProvides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality.ENERGY STAR
This model is an ENERGY STAR certified Uninterruptible Power Supply (UPS) system. ENERGY STAR is the trusted, government-backed symbol for energy-efficient products and practices that help save money and protect the environment.FeaturesHigher Capacity UPS for Longer RuntimesTo determine the size of the UPS that you need, identify the total power load (measure in VA/Watts) of the connected equipment, along with the amount of runtime required (in minutes). Also, think about any equipment that might be connected to the UPS in the future, which could affect the calculations for load & runtime.Estimating expected UPS runtimes can be challenging, particularly when the consistency of the utility power is not well known. Selecting a UPS with a load capacity 30-35% above the required power load offers the advantage of longer runtimes. This can lower the risk of overloading the UPS & causing an unnecessary UPS shutdown.Although the initial outlay of a UPS increases with its size because of the higher capacity required for components, long-term operating costs typically decrease. When a UPS operates below maximum capacity, it reduces the stress on components. Sizing a UPS to run loads significantly lower than its capacity also increases spare capacity for future growth, along with extending runtimes.Efficient Remote ManagementThe Smart App Series offers full-featured network UPS management capabilities with the PowerPanel Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).Safe ShutdownThe PowerPanel Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.Programmable Outlet ControlSmart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.Sine Wave PowerIn the U.S., utility companies provide power to households and offices by distributing single phase alternating current (AC) power at a frequency of 60 Hz. Electrical power can be graphically depicted as a sine wave whereby the electrical signal alternates from +120 volts to -120 volts at a rate of 60 times per second (60 Hz). To enable more efficient operation of large, heavy equipment, utility companies provide commercial and industrial locations with three phase AC power which consists of three overlapping sine waves offset by 120 degrees.
Although utility companies strive to distribute 100% sine wave power, many factors can introduce electrical noise into the AC power signal in the form of sine wave distortions and as voltage sags, surges, spikes, or other irregularities. Sine wave power is important for the optimal functioning of sensitive desktop computers and related peripheral equipment. Without sine wave power output, microprocessor-based equipment can become inoperative or sustain damage from power signal distortions.Active Power Factor Correction Supplies for IT Equipment
During the past thirty years, people have become more aware of the amount of energy used by IT equipment and devices. For many years, desktop computers and workstations inefficiently consumed power, partly due to the design of the power supplies which transformed AC power (from the wall outlet) to DC power (used by computers). This voltage transformation was relatively inefficient as reflected in low power factor ratings.In 1992, the U.S. Environmental Protection Agency (EPA), in collaboration with advocates in the IT industry, developed the ENERGY STAR program to prompt the development of energy-efficient products. Today this program is recognized as an international standard.To comply with ENERGY STAR standards, manufacturers of desktop and workstation computers incorporate Active Power Factor Correction (Active PFC) as part of the engineering designs, enabling energy efficiencies of 95% or higher. Computers with Active PFC power supplies require sine wave AC power, as supplied by utility companies, for trouble-free operation. For this reason, sine wave UPS systems have become the best choice for backup power.Simulated or stepped sine wave power, provided by entry-level UPS systems, may be problematic or incompatible with Active PFC devices. Sine wave power varies continuously from positive to negative. Simulated sine wave power mimics a sine wave by using a squared-off approximation. Due to this approximation, simulated sine wave power momentarily creates a zero power gap. When power is interrupted, a computer with an Active PFC power supply may not recognize incoming simulated sine wave power due to the zero output present in the approximated wave. This could cause the system to unexpectedly shut down or sustain system component stress.
Typical Applications
Department Servers
Storage Devices