Ad9850 Dds DDS Signal Generato Continual Adjust 8-9V Would Be The Ideal Voltage For Outdoors For Home For Short Time Testing For Work

Ad9850 Dds DDS Signal Generato Continual Adjust 8-9V Would Be The Ideal Voltage For Outdoors For Home For Short Time Testing For Work
sku: 2945345289
ACCORDING TO OUR RECORDS THIS PRODUCT IS NOT AVAILABLE NOW
$28.59
Shipping from: United States
   Description
Ad9850 Dds DDS Signal Generato Continual Adjust 8-9V Would Be the Ideal Voltage for Outdoors for Home for Short Time Testing for Work Specification: Features: This is a 0~55MHz DDS Signal Generator. It is based on AD9850 chip and is very easy to operate. Supports 0~55MHz continual adjust at 1Hz step. This generator has 78L05 voltage regulate. Input current at 200MA input voltage 8-9V would be the ideal voltage. Input voltage of 12V can only be used for short time testing otherwise will cause heat to board. 5p/6p connect to encoder as per photo. 7p of the middle connects to digital input. 14p 8V GND is 8V power supply from main board. If powered by main board DDS does not need independent power supply. 1~6 correspond to 6 frequency bands: 3.8 7 9 14 18 or 21 27 or 29. ISB USB CW are the three mode choices. DT is signal from main board. Keys & Connection interfaces: ENC: Encoder switch MEM: Switch for memory mode VFO: Transfer from VFO A to VFO B or from VFO B to VFO A. SSB: Working mode change: circulate from USB LSB AM CW and on and on... RIT: Fine tuning to receiving frequency CAL: Set functions KB-1 and KB-2 have common shared pin but is not GND How to operate: Press CAL power on then we enter setting screen. Let go/release CAL. A: ENABLE 6XREFCLE: setting chip clock mode adjust frequency encoding setting. AD9851 set to 6-multiply frequency AD9850 set to 1multiply frequency. Press CAL then quickly release to enter step B. B: DDS-SYSTEM-CLK: Chip working frequency setting. Use encoder switch to adjust value. Operate in accordance with STEP key. AD9851 set at oscillator 6-multiply channel AD9850 set at actual output of oscillator. Press CAL then quickly release to enter step C. C: MIN_RX_DDS_FREQ: Setting minimum working frequency. Use encoder switch to adjust value and in accordance with STEP key. Press CAL then quickly release to enter step D. D: _RX_DDS_FREQ: Setting maximum working frequency. Use encoder switch to adjust value and in accordance with STEP key. Smaller than 60MHz would be OK . Press CAL then quickly release to enter step E. E: SSB_OFFSET: Fine tuning for SSB working mode. Use encoder switch to adjust value and in accordance with STEP key. Press CAL then quickly release to enter step F. F: CW_OFFSET: Fine tuning for CW working mode. Use encoder switch to adjust value and in accordance with STEP key. Press CAL then quickly release to enter step G. G: OFFSET_FREQ: Setting of offset Frequency. e.g set to 9MHz or 10.7MHz use encoder switch to adjust value and in accordance with STEP key. Press CAL then quickly release to enter step H. H: MULTIPLIER: multiply setting for frequency. Should be set as 1 press CAL then quickly release to enter step I: I: Screen displays word SAVE automatically save the above setting and returns to normal working. Specification: Weight:115g Size: Approx. 8.2 x 4.5cm/3.2 x 1.8inch Notes: 1. DDS SYSTEM CLK: can use frequency tester to get 30MHz oscillator multiply the tested value at 6 then put the multiplied value here. If using AD9851 make initial setting at 180000000. 2. OFFSET FREQ: can be set as + or - . Rotate encoder switch to change value press STEP key then rotate encoder switch to adjust step.
   Price history chart & currency exchange rate

Customers also viewed