1PCS Nuclear Radiation Thermoluminescence Personal Dosimeter Tablets
QIFEI
артикул: 5087688035
СОГЛАСНО НАШИМ ДАННЫМ, ЭТОТ ПРОДУКТ СЕЙЧАС НЕ ДОСТУПЕН
$13.79
Доставка из: США
Описание
Features: *Brand new and high quality *Made of high quality material strong and durable *Nuclear radiation thermoluminescence has good energy response high sensitivity little environmental impact and is easy to use. This model can measure Χ and γ by default. *Scope of application: Widely used in fields such as radiation protection radiation medicine radiobiology geology archaeology and environmental protection factories and mines. *Instructions for on-site use: A set of radiation metering discs comes with two metering discs which are clipped to the pocket of your work clothes and will absorb the radiation from your surrounding environment. *Test Description: This product itself will not display any data just remember the radiation amount of your environment. If the application requires it you can go to the local ( control center) to test the data. *If it is industrial flaw detection you need to go to the local (Environmental Protection Bureau) to test the data. Use: *Annealing at 240℃±2℃ for 10 minutes. Place the detector in the iron plate and level it. When the temperature of the annealing furnace rises to 240℃±2℃ put it into the oven. When the temperature rises to 240℃±2℃ again record the time. After 10 minutes take it out and quickly put it in the oven. Cool down the metal plate (the faster the cooling speed the better the temperature cannot exceed 240℃±2℃ otherwise the sensitivity will decrease). Put the cooled thermoluminescent sheet into the dosage box for later use; *Test: Use the corresponding thermoluminescence dose instrument adjust the light source sensitivity 30 minutes after turning on the machine and use the M2 program (ie: the heating rate is 15°C/S the constant temperature is 135°C/8S the second constant temperature is 240°C/ 12S) measure after more than 3 empty measurements. *Note: It is forbidden to touch the detector directly with hands. Detectors contaminated by dust should be cleaned with alcohol. Dry them after the alcohol evaporates before use. Place them in a ventilated and dry place to avoid light exposure. Do not mix detectors with each batch after use. Other batches of detectors are mixed. Detectors with serious contamination and incorrect annealing should be scrapped. Specification: *Product Name: Radiometric Thermoluminescent Film *Color: Green/Blue/Yellow/Green/Pink (optional) *Packaging: 1 piece Package includes: 1 x Radiometric Thermoluminescent Sheet Notes: 1. Due to various factors such as display brightness and light brightness the actual color of the product may be slightly different from the website picture. 2. Please allow a slight deviation between the data and the manual measurement.
График изменения цены & курс обмена валют